ce_switchport - Manages Layer 2 switchport interfaces on HUAWEI CloudEngine switches.

New in version 2.4.

Synopsis

  • Manages Layer 2 switchport interfaces on HUAWEI CloudEngine switches.

Parameters

Parameter Choices/Defaults Comments
access_vlan
If mode=access, used as the access VLAN ID, in the range from 1 to 4094.
interface
required
Full name of the interface, i.e. 40GE1/0/22.
mode
    Choices:
  • access
  • trunk
The link type of an interface.
native_vlan
If mode=trunk, used as the trunk native VLAN ID, in the range from 1 to 4094.
state
    Choices:
  • present
  • absent
  • unconfigured
Manage the state of the resource.
trunk_vlans
If mode=trunk, used as the VLAN range to ADD or REMOVE from the trunk, such as 2-10 or 2,5,10-15, etc.

Notes

Note

  • When state=absent, VLANs can be added/removed from trunk links and the existing access VLAN can be ‘unconfigured’ to just having VLAN 1 on that interface.
  • When working with trunks VLANs the keywords add/remove are always sent in the port trunk allow-pass vlan command. Use verbose mode to see commands sent.
  • When state=unconfigured, the interface will result with having a default Layer 2 interface, i.e. vlan 1 in access mode.

Examples

- name: switchport module test
  hosts: cloudengine
  connection: local
  gather_facts: no
  vars:
    cli:
      host: "{{ inventory_hostname }}"
      port: "{{ ansible_ssh_port }}"
      username: "{{ username }}"
      password: "{{ password }}"
      transport: cli

  tasks:
  - name: Ensure 10GE1/0/22 is in its default switchport state
    ce_switchport:
      interface: 10GE1/0/22
      state: unconfigured
      provider: '{{ cli }}'

  - name: Ensure 10GE1/0/22 is configured for access vlan 20
    ce_switchport:
      interface: 10GE1/0/22
      mode: access
      access_vlan: 20
      provider: '{{ cli }}'

  - name: Ensure 10GE1/0/22 only has vlans 5-10 as trunk vlans
    ce_switchport:
      interface: 10GE1/0/22
      mode: trunk
      native_vlan: 10
      trunk_vlans: 5-10
      provider: '{{ cli }}'

  - name: Ensure 10GE1/0/22 is a trunk port and ensure 2-50 are being tagged (doesn't mean others aren't also being tagged)
    ce_switchport:
      interface: 10GE1/0/22
      mode: trunk
      native_vlan: 10
      trunk_vlans: 2-50
      provider: '{{ cli }}'

  - name: Ensure these VLANs are not being tagged on the trunk
    ce_switchport:
      interface: 10GE1/0/22
      mode: trunk
      trunk_vlans: 51-4000
      state: absent
      provider: '{{ cli }}'

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key Returned Description
changed
boolean
always
check to see if a change was made on the device

Sample:
True
end_state
dict
always
k/v pairs of switchport after module execution

Sample:
{'access_vlan': '20', 'interface': '10GE1/0/22', 'mode': 'access', 'switchport': 'enable'}
existing
dict
always
k/v pairs of existing switchport

Sample:
{'access_vlan': '10', 'interface': '10GE1/0/22', 'mode': 'access', 'switchport': 'enable'}
proposed
dict
always
k/v pairs of parameters passed into module

Sample:
{'access_vlan': '20', 'interface': '10GE1/0/22', 'mode': 'access'}
updates
list
always
command string sent to the device

Sample:
['10GE1/0/22', 'port default vlan 20']


Status

This module is flagged as preview which means that it is not guaranteed to have a backwards compatible interface.

Maintenance

This module is flagged as community which means that it is maintained by the Ansible Community. See Module Maintenance & Support for more info.

For a list of other modules that are also maintained by the Ansible Community, see here.

Author

  • QijunPan (@CloudEngine-Ansible)

Hint

If you notice any issues in this documentation you can edit this document to improve it.

© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/2.6/modules/ce_switchport_module.html