Synopsis
- Manages F5 BIG-IP GTM (now BIG-IP DNS) TCP monitors.
 
Parameters
| Parameter | Choices/Defaults | Comments | |
|---|---|---|---|
|   ignore_down_response    boolean    |   
  |    Specifies the monitor allows more than one probe attempt per interval.  When   yes, specifies the monitor ignores down responses for the duration of the monitor timeout. Once the monitor timeout is reached without the system receiving an up response, the system marks the object down.When   no, specifies the monitor immediately marks an object down when it receives a down response.When creating a new monitor, if this parameter is not provided, the default value will be   no. |  |
|   interval    integer    |    The interval specifying how frequently the monitor instance of this template will run.  If this parameter is not provided when creating a new monitor, the default value will be 30.  This value must be less than the   timeout value. |  ||
|   ip    string    |    IP address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value will be '*'.  If this value is an IP address, a   port number must be specified. |  ||
|   name    string / required    |    Monitor name.   |  ||
|   parent    string    |   Default: "/Common/tcp"   |    The parent template of this monitor template. Once this value has been set, it cannot be changed. By default, this value is the   tcp parent on the Common partition. |  |
|   partition    string    |   Default: "Common"   |    Device partition to manage resources on.   |  |
|   port    string    |    Port address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value will be '*'. Note that if using an IP address, you must specify a value between 1 and 65535.   |  ||
|   probe_timeout    integer    |    Specifies the number of seconds after which the system times out the probe request to the system.  When creating a new monitor, if this parameter is not provided, then the default value will be   5. |  ||
|   provider    dictionary    added in 1.0.0 of f5networks.f5_modules    |    A dict object containing connection details.   |  ||
|   auth_provider    string    |    Configures the auth provider for to obtain authentication tokens from the remote device.  This option is really used when working with BIG-IQ devices.   |  ||
|   no_f5_teem    boolean    |   
  |    If   yes, TEEM telemetry data is not sent to F5.You may omit this option by setting the environment variable   F5_TEEM. |  |
|   password    string / required    |    The password for the user account used to connect to the BIG-IP.  You may omit this option by setting the environment variable   F5_PASSWORD.aliases: pass, pwd  |  ||
|   server    string / required    |    The BIG-IP host.  You may omit this option by setting the environment variable   F5_SERVER. |  ||
|   server_port    integer    |   Default: 443   |    The BIG-IP server port.  You may omit this option by setting the environment variable   F5_SERVER_PORT. |  |
|   timeout    integer    |    Specifies the timeout in seconds for communicating with the network device for either connecting or sending commands. If the timeout is exceeded before the operation is completed, the module will error.   |  ||
|   transport    string    |   
  |    Configures the transport connection to use when connecting to the remote device.   |  |
|   user    string / required    |    The username to connect to the BIG-IP with. This user must have administrative privileges on the device.  You may omit this option by setting the environment variable   F5_USER. |  ||
|   validate_certs    boolean    |   
  |    If   no, SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.You may omit this option by setting the environment variable   F5_VALIDATE_CERTS. |  |
|   receive    string    |    The receive string for the monitor call.   |  ||
|   reverse    boolean    |   
  |    Instructs the system to mark the target resource down when the test is successful. This setting is useful, for example, if the content on your web site home page is dynamic and changes frequently, you may want to set up a reverse ECV service check that looks for the string Error.  A match for this string means the web server was down.  To use this option, you must specify values for   send and receive. |  |
|   send    string    |    The send string for the monitor call.   |  ||
|   state    string    |   
  |    When   present, ensures the monitor exists.When   absent, ensures the monitor is removed. |  |
|   timeout    integer    |    The number of seconds in which the node or service must respond to the monitor request. If the target responds within the set time period, it is considered up. If the target does not respond within the set time period, it is considered down. You can change this number to any number you want, however, it should be 3 times the interval number of seconds plus 1 second.  If this parameter is not provided when creating a new monitor, the default value will be 120.   |  ||
|   transparent    boolean    |   
  |    Specifies whether the monitor operates in transparent mode.  A monitor in transparent mode directs traffic through the associated pool members or nodes (usually a router or firewall) to the aliased destination (that is, it probes the   ip-port combination specified in the monitor).If the monitor cannot successfully reach the aliased destination, the pool member or node through which the monitor traffic was sent is marked down.  When creating a new monitor, if this parameter is not provided, then the default value will be   no. |  |
Notes
Note
- For more information on using Ansible to manage F5 Networks devices see https://www.ansible.com/integrations/networks/f5.
 - Requires BIG-IP software version >= 12.
 - The F5 modules only manipulate the running configuration of the F5 product. To ensure that BIG-IP specific configuration persists to disk, be sure to include at least one task that uses the f5networks.f5_modules.bigip_config module to save the running configuration. Refer to the module’s documentation for the correct usage of the module to save your running configuration.
 
Examples
- name: Create a GTM TCP monitor
  bigip_gtm_monitor_tcp:
    name: my_monitor
    ip: 1.1.1.1
    port: 80
    send: my send string
    receive: my receive string
    state: present
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost
- name: Remove TCP Monitor
  bigip_gtm_monitor_tcp:
    name: my_monitor
    state: absent
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost
- name: Add TCP monitor for all addresses, port 514
  bigip_gtm_monitor_tcp:
    name: my_monitor
    port: 514
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost
   Return Values
Common return values are documented here, the following are the fields unique to this module:
| Key | Returned | Description | 
|---|---|---|
|   ignore_down_response    boolean    |  changed |   Whether to ignore the down response or not.  Sample:  True   |  
|   interval    integer    |  changed |   The new interval in which to run the monitor check.  Sample:  2   |  
|   ip    string    |  changed |   The new IP of IP/port definition.  Sample:  10.12.13.14   |  
|   parent    string    |  changed |   New parent template of the monitor.  Sample:  tcp   |  
|   port    string    |  changed |   The new port on which the monitor checks the resource.  Sample:  8080   |  
|   probe_timeout    integer    |  changed |   The new timeout in which the system will timeout the monitor probe.  Sample:  10   |  
|   receive    string    |  changed |   The new receive string for this monitor.  Sample:  tcp string to receive   |  
|   reverse    boolean    |  changed |   The new value for whether the monitor operates in reverse mode.   |  
|   send    string    |  changed |   The new send string for this monitor.  Sample:  tcp string to send   |  
|   timeout    integer    |  changed |   The new timeout in which the remote system must respond to the monitor.  Sample:  10   |  
|   transparent    boolean    |  changed |   The new value for whether the monitor operates in transparent mode.   |  